Revised USP Chapter <31> and New Chapter <1331> on Volumetric Apparatus Published for Comments

Recommendation
13-15 May 2025
Vienna, Austria
Practical Approaches for USP General Chapter <1058> Compliance in the QC Laboratory
In the Pharmacopeial Forum, PF 49(5), two USP chapters related to volumetric apparatus were published for comments. It is proposed to make several changes in chapter <31> Volumetric Apparatus. Furthermore, a new general chapter <1331> Use and Calibration of Volumetric Apparatus has been developed.
A chapter numbered below 1000 becomes applicable and compendially required respect where it is referenced in a monograph or another applicable general chapter numbered below 1000 or in general notices. General chapters numbered 1000 to 1999 are for informational purposes only. They are considered interpretive and are intended to provide information on, give definition to, or describe a particular subject.
Comments on both chapters can be submitted from now on until 30 November 2023. The drafts are available via the USP website access point.
USP Chapter <31> Volumetric Apparatus
The proposal is based on the version of the chapter official as of 01 November 2020. The briefing notes list a couple of changes, including the following:
- "Clarify that a calibration temperature of 27° C is also performed in other countries that have adopted that reference temperature. Temperature correction might be required when ambient temperature differs from the reference temperature. [...]
- Provide alternatives when the limits of error are not met or not suitable at the conditions of use. [...]
- Update terminology to the International Vocabulary of Metrology [...]
- Introduce considerations for piston-operated volumetric apparatus (POVA) in several paragraphs when appropriate. [...]
- For plastic volumetric apparatuses, introduce temperature correction and equilibration, as well as limits of error. [...]"
USP Chapter <1331> Use and Calibration of Volumetric Apparatus
In the briefing notes, it is stated that "this new general chapter has been developed to provide guidelines on methods validating the original calibration of volumetric apparatus described in Volumetric Apparatus <31>, their appropriate usage, and for periodic recalibrations as needed."
The chapter is structured as follows:
- Introduction
- Scope
- User considerations
- Measurement considerations
- Calibration process
- Calculations
- Glossary
- References
- Additional sources of information
Related GMP News
07.05.2025Public Consultation on ICH M13B Guideline on Bioequivalence launched in Switzerland
07.05.2025BioPhorum publishes Guidance for ICH Q2(R2) and Q14 Implementation
23.04.2025OTC Drug Production Ceased after FDA Warning Letter
23.04.2025EMA publishes Draft of ICH M13B Guideline on Bioequivalence
16.04.2025EMA publishes four new product-specific Bioequivalence Guidance
09.04.2025Missing Tests and Altered Records: FDA Warns Chinese OTC Manufacturer