Have a brief look at the training here (link to Vimeo).
Book the Main Course in combination with the Post-Course Impact of Annex 1 Revision on Cleaning Validation and save € 200!
Target Group
The Main Course and the Post-Course are directed at staff of R&D, production and quality assurance involved in cleaning validation. They also address engineering companies and manufacturers of cleaning devices/equipment interested in learning more about the pharmaceutical industry’s viewpoint and in exchanging experiences.
Objectives
Many questions relative to cleaning validation are still open and have to be answered within the companies:
- What does the cleaning validation concept have to look like to be GMP-compliant and cost-effective?
- Which risk analyses are applicable to cleaning validation?
- How helpful can a riboflavin test be?
- Which maximum value is scientifically acceptable, especially in the field of APIs?
- Which sampling procedure is appropriate for which process and facility?
- How can you cut costs by means of bracketing?
- How are critical areas defined?
- Is cleaning evaluation the solution for seldom manufactured products?
- Which microbiological maximum values are valid in the areas of non-sterile dosage forms and APIs?
and
- Special aspects of cleaning validation in biotech API plants
These questions will also be discussed with the help of practical examples.
Background
In the manufacture of medicinal products and APIs, the cleaning of facilities and equipment is an important measure to avoid contamination and cross contamination. In compliance with the GMP regulations, cleaning is performed and documented according to the described procedures. In the past, cleaning effectiveness was often monitored only visually. However, residuals of APIs and excipients as well as of detergents are increasingly an issue in inspections and audits. The success of cleaning procedures has to be validated. In addition to the FDA “Guide to Inspection – Validation of Cleaning Validation Processes”, the PIC/S document PI 006 and Annex 15 address cleaning validation in a separate chapter. Moreover, the ICH Guideline Q7 “GMP for APIs” also requires cleaning validation – as well as two Guidelines by APIC, the association of European API manufacturers.
A Guideline from EMA on Dedicated Facilities and Exposure Limits for Cleaning Validation and the revised Annex 15 deal now with a PDE (Permitted Daily Exposure) approach.
The Annex 1 revision and it’s Contamination Control Strategy (CCS) also has an impact, especially on Cleaning Validation for sterile dosage forms.
Programme
Regulatory Requirements
- EU GMP Guideline Part I, II and III
- EU GMP Guideline Annex 15
- EMA “Shared Facilities Guideline” (incl. PDE concept)
- PIC/S PI 006
- APIC Cleaning Validation Guidance for APIs
- PDA TR 29 – “Points to Consider for Cleaning Validation
- ISPE Cleaning Validation Life Cycel – Applications, Methods, and Controls
- FDA 21 CFR 211.67
- FDA Guide to Inspection – Validation of Cleaning Processes
Practical Pre-Requisites I – Hygienic Equipment Design
- What is hygienic design?
- Material aspects
- WIP/CIP aspects
- Riboflavin test
Practical Pre-Requisites II – Cleaning Process Development
- Developing a cleaning process – which steps are necessary?
- TACT
- Which residues are common
- Type and selection of cleaners
- CIP vs WIP vs manual cleaning
- Cleaning Documentation
Sampling during Cleaning Validation
- How to define sampling points?
- Sampling techniques
- Swab
- Rinse
- Coupons
- Analytical requirements
Cleaning Validation – incl. Practical Approaches
- Cleaning Validation Concepts
- Bracketing
- Hold time studies (DHT, CHT)
- Cleaning Validation Risk Management
- Cleaning Validation Plan
- Cleaning Validation Report
- Cleaning Validation life cycle (Revalidation, Ongoing Cleaning Verification)
- Cleaning Evaluation
Workshop – Setting Sampling Points
- Setting sampling points on a risk-based Approach – what to consider
- Sampling point selection based on sampling technique and analytical method
- Different sampling points for different purposes
Handling Deviations and OOS during Cleaning Validation and Ongoing Cleaning Verification
- What is an OOS, what a deviation regarding Cleaning Validation?
- GMP-compliant documentation of OOS and deviations
- CAPA
Workshop – Case studies of Non-Conformities during Cleaning Validation and Ongoing Cleaning Verification
- Is always the cleaning process to blame?
- Which actions are adequate based on the Investigation and root cause?
- Actions depending on the time-point of detecting the Non-Conformity
- Does a Non-Conformity mean revalidation?
- Does a Non-Conformity always lead to Batch rejection?
Special Topics of Cleaning Validation
- Segregation & shared facility Guideline
- Cleaning Validation in Biologics & Biotech production
- Differences between chemical and biotech APIs
- Acceptance criteria for biotech APIs
- Analytical methods to detect biotech APIs in Cleaning Validation
Q & A sessions
Five Q &A sessions (two on day 1 and on day 2 of the main Course and one during the post-course) ensure interaction and that your questions are answered.
Five Q &A sessions (two on day 1 and on day 2 of the main Course and one during the post-course) ensure interaction and that your questions are answered.
Further Information
Technical Requirements
We use Webex for our live online training courses and webinars. At www.gmp-compliance.org/training/online-training-technical-information you will find all the information you need to participate in our events and you can check if your system meets the necessary requirements to participate. If the installation of browser extensions is not possible due to your rights in the IT system, please contact your IT department. Webex is a standard nowadays and the necessary installation is fast and easy.
Conference language
The official conference language will be English.
The official conference language will be English.
Fees (per delegate, plus VAT)
ECA Members € 1,890
APIC Members € 1,990
Non-ECA Members € 2,090
EU GMP Inspectorates € 1,045
The conference fee is payable in advance after receipt of invoice.
ECA Members € 1,890
APIC Members € 1,990
Non-ECA Members € 2,090
EU GMP Inspectorates € 1,045
The conference fee is payable in advance after receipt of invoice.
Book the Main Course in combination with the Post-Course Impact of Annex 1 Revision on Cleaning Validation and save € 200! Book combination.
Presentations/Certificate
The presentations will be made available to you prior to the Live Online Training as PDF files. After the event, you will automatically receive your certificate of participation.
The presentations will be made available to you prior to the Live Online Training as PDF files. After the event, you will automatically receive your certificate of participation.
Contact
Questions regarding content:
Mr Sven Pommeranz, +49 (0) 62 21 84 44 47, pommeranz@concept-heidelberg.de.
Questions regarding Organisation:
Ms Julia Grimmer, +49(0)6221/84 44 44, julia.grimmer@concept-heidelberg.de.
Date & Time
Tue., 28 April 2026, 09.00 - 17.00 h
Wed., 29 April 2026, 08.30 - 16.30 h
All times mentioned are CEST.
Wed., 29 April 2026, 08.30 - 16.30 h
All times mentioned are CEST.
Costs
| ECA-Member*: | € 1890,- |
| Non ECA Member*: | € 2090,- |
| EU/GMP Inspectorates*: | € 1045,- |
| APIC Member Discount*: | € 1990,- |
(All prices excl. VAT). Important notes on sales tax.
* also payable by credit card
Additional dates on-site
Additional dates on-site
not available
not available
This course is part of the GMP Certification Programme "ECA Certified Validation Manager"
Do you have any questions?
Please contact us:
Tel.: +49 6221 8444-0
E-Mail: info@gmp-compliance.org
Testimonials about our courses and conferences