Handling of Highly Potent Compounds

Handling of Highly Potent Compounds

Vienna, Austria

Course No 15231


Costs

This training/webinar cannot be booked. To find alternative dates for this training/webinar or similar events please see the events list by topic.

For many training courses and webinars, there are also recordings you can order and watch any time. You can find these recordings in a list sorted by topic.

Or simply send us your inquiry by using the following contact form.

* also payable by credit card American Express Visa Mastercard

If you have any questions, please contact us:
Tel.: +49 (0)6221 / 84 44 0 E-Mail: info@gmp-compliance.org

Speakers

Dr Stefan Benkel, Lonza

Dr Andreas Flückiger, F. Hoffmann-La Roche

Rainer Glöckler, Swissfillon

Jorge Guerreiro, Hovione

Dr Rainer Nicolai, F. Hoffmann-La Roche

Dr Andreas Nixdorf, SGS Institut Fresenius

Dr Peter Pöschl, Holopack

Viktor Schnyder, Lugaia

Dr Harald Stahl, GEA

Objectives

The main focus of this conference is on the connection of handling highly potent APIs and the usage of disposable equipment. GMP and safety aspects will be covered and examples from real life will be shown. Amongst others, the following topics will be discussed:

  • Definition of the appropriate containment level
  • Available single-use components and solutions
  • GMP and ATEX requirements for single-use equipment
  • Implementation of disposables in pharmaceutical processes
  • Qualification of disposable equipment
  • Risk handling strategies

Background

The usage of disposable and single-use equipment in the biopharmaceutical production has been growing for years. Well-known examples are disposable bags, hoses and bioreactors. But also in the manufacture of small molecule APIs, the usage of single-use equipment is increasing.

The pharmaceutical industry is now facing a new challenge after a long-time experience had been won with product contact interaction of stainless steel, ceramics or other alloys. Whereas the compatibility of traditional materials is (almost) no topic, plastic material raises discussions. Leachables and Extractables are the big topic here. Many studies have been done already, focusing on effects in aqueous buffer solutions. But coming to the production of small molecule APIs much fiercer conditions have to be considered with respect to organic solvents.
Another issue is caused by the advantages of single-use equipment. It is ready to use and does not have to be cleaned before use. So GMP-relevant steps are shifted towards the supplier of the plastic equipment who has to take care of the GMP-compliant production of his equipment, an appropriate packaging and the necessary documentation. The responsibility remains with the pharmaceutical manufacturer though. Also the handling of disposable equipment is much more demanding compared to robust stainless steel equipment. The training of the production staff gets thus even more important.
Furthermore, the SU equipment does not have to be cleaned after use which is - of course - one of the biggest advantages.

The containment aspect when manufacturing or handling potent APIs is independent from the material of the equipment. The production equipment has to be tight, not only from the GMP aspect to protect the product from the environment, but also from the occupational health point of view to protect the worker from the product. Both have to be proven by measurements.
Yet, with the flexible plastic equipment being much more sensitive to injuries compared to stainless steel equipment, optimised accident scenarios have to be in place.

Besides, there is another advantage of disposable systems. The shift to more single-use systems also brings a higher flexibility to production. More and more single-use isolators are used instead of fixed and immobile isolators - not only to avoid cleaning effort but also to minimize change-over times.

Target Group

Managers and technical experts from production, development and occupational health &
safety, responsible for production, design and installation of equipment, selection and testing of components are the target group of this conference.

Programme

Toxicological fundamentals in the evaluation of highly potent APIs

  • Legal requirements regarding worker safety and GMP requirements to control cross
  • contamination
  • Assessing the hazard: potency and toxicity of APIs and intermediates
  • Usage of default values, category- and TTC-based approaches
  • Usage of occupational hygiene data in the context of cross contamination control
Overview: available SU Systems for small and large scale API manufacture
In this presentation manufacturing steps of small and large scale API manufacturing are
compared and available disposable equipment for each step is shown and discussed
  • Processing
  • Separation
  • Transfer
  • Sampling
  • Filling
Films and Film Handling according to Pharma Requirements
  • Film Manufacturing, processing, transportation and packaging
  • Clean room conditions for film manufacturing and processing
  • Available films and film materials
  • ATEX vs GMP certification – how to combine both requirements
  • How to seal SU equipment: Crimping vs Welding
  • Proof of tightness: SMEPAC measurements
A pragmatic approach to Leachable/Extractable evaluation
  • API and disposable material interactions, biocompatibility
  • GMP and ISO certificates
  • Designing a L&E study
  • Usage of risk analysis tools
  • Industrial practice and examples
Single Use Equipment - Operational Aspects and Qualification of Material
Using “Single Use Equipment” within the chemical production of API has tremendous advantages, but there are also plenty obstacles to overcome. Typical areas of conflicts are the needs of the production environment such as fulfilling ATEX rules and having a wide range of operational parameters like pressure and temperature versus the unquestionable need of qualifying the material of such systems. As these materials are in many cases different types of plastic there are wide-spread uncertainties how to handle e.g. material certificates.

Case Study Holopack: Implementation of a flexible and single-use Isolator
  • Usage of a single-use isolator for open API weighing processes
  • Contamination-free transfer
  • Safety vs GMP aspects
  • Qualification
  • Necessary supplier documents (certificates, etc.)
  • Containment performance (measurements/results)
Case study Hovione: Manufacturing and Release of Potent APIs made easy
  • Installations design to manufacture/release potent compounds
  • Containment strategies used (practical examples)
  • Qualification of the installation / surrogate testing
  • Procedures and training
Case study Lonza: Manufacturing of Antibody Drug Conjugates using Single Use Equipment
  • High Potent classification at Lonza
  • Facility Layout
  • Safety vs. Quality
  • ISO/GMP Classification
  • Pressure Cascade
  • Single-Use Equipment
  • Advantages/Disadvantages
  • Equipment used
  • Single-Use Experiences
  • Operational Hygiene: results
Case Study Swissfillon: Single Use <-> „Final Fill of HPAPIs” - A Contradictory Situation?
  • Single Use in its established environment
  • Environment – Health – Safety Policy of Swissfillon
  • Implementing “Single Use” into compounding and Final Fill of HPAPIs
  • Design Criteria to be met
  • Layouts
  • Pros and Cons
  • Conclusion

Go back